Careful inspection of fire dampers according to technical standards.
Our service ensures your safety
Our services include the thorough inspection and testing of fire dampers in accordance with the strict requirements of ÖNORM H6031. For transparent and comprehensible documentation, we use specially developed checklists that meet the requirements of ÖNORM H6031. We provide our customers with these checklists in both printed and electronic form. Regardless of whether a single fire damper or more than 800 need to be checked - we always guarantee a complete overview and the highest level of accuracy. If defects are identified, our customers receive a detailed recommendation for action in the form of a report and detailed documentation. Thanks to our extensive network, we are able to not only identify problems, but also competently meet all requirements in the areas of hygiene and fire protection in ventilation systems. Trust in our expertise for your safety.
"Fire damper - tested and safe!"
Upon closer inspection, the seemingly simple check of a fire damper according to the requirements of ÖNORM H6031 can reveal alarming results. It is common for fire dampers to be classified as “professionally inspected” even though they are either inaccessible or not functioning properly. In order to provide clarity and education, we would like to explain to our customers the full scope of our services required for a proper test of a fire damper in accordance with ÖNORM H6031.
The visual inspection of a fire damper includes several important aspects that should ensure that the flaps are properly installed and ready for use. Items reviewed include: 1. Compliance with the latest valid inventory plans 2. Determination of relevant structural changes or Facility changes 3. Fire damper design according to test report (K90) or classification report/declaration of performance (EI90) 4. Installation in accordance with ÖNORM H 6031 and manufacturer's instructions 5. Termination between BSK and building structure 6. Classification "K90" or "EI90" 7. ÜA marking or CE marking 8. Information about the manufacturer 9. Corrosion/contamination 10. Condition of the damper blade and seals 11. Damper identification within the system 12. Limit switches, motor/drive and connections 13. Terminal box and wiring
The functional control of a fire damper includes various steps to ensure that the flap works properly and can fulfill its protective function in the event of a fire. Items checked include: 1. Close the flap at least three times (while present on site) 2. Proper/smooth opening and closing of the closure element (visual/acoustic assessment) 3. Electric remote release and opening of the flap via the central Fire alarm system, if technically possible 4. Check the visual display "closed" and “open” at the BSK; Checking the message of the limit switches and all control displays 5. Checking the holding function in the safety position or fixing the lock after reaching the safety position This functional control ensures that the Fire damper works properly in an emergency and contributes to to prevent the spread of fire and smoke in a building.
Checking and logging fire dampers during execution
Defects discovered during an inspection. - Damper leaf outside the firewall - Damper leaf broken - Cold smoke seal defective- Garbage in the ventilation network leads to malfunctions of the fire damper